防泄漏托盤符合美國環(huán)境保護署(EPA)EPA 40 CFR 264.175與SPCC規(guī)范、及美國國家消除污染排放制度(NPDES)
SYSBEL SPCC 參數(shù)
可放200L桶個數(shù) 盛漏量(加侖/升) 承重量(Kgs.)
外形尺寸
(高×長×寬/cm)
叉車操作 黃色 型號
4 63/236 2722 30x135x135 四向操作(叉槽寬度34cm) SPP304
盛漏托盤系列之聚乙烯盛漏托盤
該款盛漏托盤具備以下特點:
1、盛漏托盤整體采用無縫隙結(jié)構(gòu)設計,防漏結(jié)構(gòu)100%通過測試,完全避免泄漏的發(fā)生;
2、主體材質(zhì):線性低密度聚乙烯,具有良好地耐酸堿腐蝕的材質(zhì),杜絕化學品泄漏時所可能產(chǎn)生的危害,可在戶外使用;
3、當出現(xiàn)泄漏時,所有液體將會沿托盤格柵自動注入托盤盛漏區(qū)域內(nèi),不會污染現(xiàn)場環(huán)境;
4、雙叉車插口便于搬運;
5、導液口設計,方便集中清理泄露液體;
6、盛漏托盤有不同型號可供您選擇,便于您合理規(guī)劃化學品或?qū)瘜W品倉庫進行整改時使用;
特別提醒:
當現(xiàn)場發(fā)生化學品泄漏時,如果泄漏的液體全部集中于托盤內(nèi)部,請專業(yè)人員即時清理;
如果泄漏的區(qū)域出現(xiàn)擴散,請專業(yè)人員使用相對應的化學品吸咐產(chǎn)品進行及時堵漏及吸收。
美國環(huán)境保護署對盛漏托盤制定了嚴格的標準 EPA 40 CFR 264.175。
(a) Container storage areas must have a containment system that is designed and operated in accordance with paragraph (b) of this section, except as otherwise provided by paragraph (c) of this section.
(a)儲存容器周圍必須有(b) 段落中要求的堵漏設備,除非滿足(c)中條件
(b) A containment system must be designed and operated as follows:
(b)堵漏設備設計安裝必須符合以下條件:
(1) A base must underly the containers which is free of cracks or gaps and is sufficiently impervious to contain leaks, spills, and accumulated precipitation
until the collected material is detected and removed;
(1) 容器底部必須有能夠盛漏的底座,保證能暫時存儲泄露物質(zhì)
(2) The base must be sloped or the containment system must be otherwise
designed and operated to drain and remove liquids resulting from leaks,
spills, or precipitation, unless the containers are elevated or are otherwise
protected from contact with accumulated liquids;
(2) 底座必須可以傾斜或者有可以排出盛漏液體的設計。除非容器本身有加高設計或禁止接觸
盛漏液體。
(3) The containment system must have sufficient capacity to contain 10%
of the volume of containers or the volume of the largest container, whichever
is greater. Containers that do not contain free liquids need not be considered
in this determination;
(3)堵漏設備必須有足夠的容量來儲存所有容器的10%或單個最大容器的泄漏物。如果容器未裝液體則不在此范疇。
(4) Run-on into the containment system must be prevented unless the collection
system has sufficient excess capacity in addition to that required in
paragraph (b)(3) of this section to contain any run-on which might enter the
system; and
(4)堵漏設備必須可以替換,除非此堵漏設備本身容量充分滿足 (b)(3)中的要求。
(5) Spilled or leaked waste and accumulated precipitation must be removed
from the sump or collection area in as timely a manner as is necessary to prevent
overflow of the collection system.
[Comment: If the collected material is a hazardous waste under part 261 of this Chapter,
it must be managed as a hazardous waste in accordance with all applicable requirements
of parts 262 through 266 of this chapter. If the collected material is discharged
through a point source to waters of the United States, it is subject to the requirements
of section 402 of the Clean Water Act, as amended.]